    Brand Name : YueXin
    Model Number : YX-IPX19BS-R400
    Certification : ISO 20653:2013, DIN 40050-9:1993, IEC60529:2013,VW 80000:2017 LV124 K-10
    Price : usd+20000-50000+pcs
    Payment Terms : T/T
    Supply Ability : 100+pcs+30
    Delivery Time : 30-45 days
    • Product Details
    • Company Profile

    Wide Use R400 Rain Test Chamber with Adjustable Spray Distance for IPX1-9K

    Wide Use R400 Rain Test Chamber with Adjustable Spray Distance for IPX1-9K


    Generl specifications:


    Dimension

    Outer : L1350*W1080*H1900/
    L400*W2400*H1500;

    Inner : W 900×D 900×H 1050(mm)

    Material

    External : steel plate;

    Internal : 304 stainless steel

    Power supply380V/50HZ
    Power18.0kw

    Product presentation:


    The IPX1-9 waterproof test chamber is a versatile device that includes 10 distinct waterproof rating standards: IPX1 through IPX9, as well as IPX4K, IPX6K, and IPX9K. Starting from IPX1, which signifies resilience against vertical water droplets, to IPX9, which demonstrates resilience against high-temperature, high-pressure water jets, the waterproof capabilities steadily escalate. The intermediate levels offer progressively stronger waterproof performance.


    • A protective cover is installed at the bottom of the drip tank to prevent the head from being hurt by the nozzle during operation.
    • The equipment uses a high-quality servo motor to drive the swing tube, so that the swing angle is more precise and the noise is low.
    • For IPX5/6 testing, here are two spray modes:up and down sweeping water spray and fixed water spray5(Spray water from back to front).
    • The spray distance(IPX9/9K) can be adjusted manually to meet the standard (125±25mm).
    • The outer layer of the water tank is pasted with thermal insulation cotton to reduce heat dissipation and ensure a constant water temperature.
    • The flow rate is automatically adjusted by an electronic flow sensor, and the flow data will be displayed on the touch screen in real time6.
    • Use a pressure gauge to display the test water pressure.
    • The sample power socket (220V, 10A) is mounted on the right wall of the inner box, which is convenient for the user to do the live test of the sample; and after the sample is powered on, the turntable rotation will be automatically adjusted to forward and reverse rotation to prevent winding 7.
    • Controller: 7-inch touch screen + PLC, using Yuexin self-developed software, which can be switched to multiple languages8.
    • Test time setting: 0-999min9.
    • Universal casters are mounted on the bottom, which has good load-bearing and easy to move and fix the equipment.

    Using environment:


    The comprehensive IPX1-9 waterproof rating standards cater to a diverse range of needs, from basic water resistance for outdoor lighting to advanced waterproofing for cycling in the rain, diving apparatus, and underwater photography equipment. Selecting the appropriate rating based on the specific usage scenario is essential.


    Standard features for IPX1/2:


    ItemParameter
    Drip area600×600mm
    Diameter of nozzles0.4mm
    Distance between nozzles20mm
    Water flow(IPX1)100.36-0.54 L/min
    Water flow(IPX2)1.08-1.26L/min
    Drip distance11200mm

    Standard features for IPX3/4K:


    ItemParameter
    Radius of swivel tube12R400
    Diameter of swivel tube800mm
    Internal diameter of swivel tube15mm
    Internal diameter of nozzle

    IPX3/4 : 0.4mm;

    IPX4K : 0.8mm

    Number of nozzles of swivel tubeSee remark13
    Distance between nozzles50mm
    Speed of rotation of the swivel tube60 degree/s
    Swing pipe angle

    IPX3 : 120º;

    IPX4/IPX4K : 350º

    Water volume flow

    IPX3(L/min) : 1.1 ;

    IPX4(L/min) : 1.8 ;

    IPX4K(L/min):15.0

    Flow error range±5%

    Standard features for IPX5/6K:


    ItemParameter
    Diameter of nozzles

    IPX5,IPX6K : 6.3mm;

    IPX6 :12.5mm

    Water flow

    IPX5 : 12.5±0.625 L/min

    IPX6 : 100.0±5.0L/min

    IPX6K : 75.0±3.75L/min

    Spray distance142.7m
    Spray directionSpray from back to front
    Spray height15<800mm
    Nozzle swing speed0-20 cycle/min

    Standard features for IPX9K:


    ItemParameter
    Spray distance125±25mm
    Number of nozzles4个
    Nozzle angle0°,30°,60°,90°
    Water flow14-16L/min
    Flow controlAutomatic adjustment
    Storage tank temperature80±5℃
    Spray pressure8000-10000Kpa
    Water jet impact0.9-1.2N
    Test time120 seconds, 30 seconds per position

    Remark:


    1 The pictures in this document are for customer reference only, and there may be color differences between the actual model and the pictures.

    2 This document only lists some test standards, which does not mean that other test requirements and standards cannot be conducted. Welcome to communicate and discuss with us.

    3 One test only at the same time. The next project can be only carried out after the current test is completed. In addition, we can provide multi-functional customized test solutions according to user requirements.

    4 Standard load-bearing upper limit of turntable is 50kg,but also can be customized per requirements.Turntables of φ200mm are provided for replacement.

    5 If the sample height exceeds 150mm, it is recommended to choose the swing spray method.

    6 Use flow sensor to adjust water flow automatically, the flow is set according to the corresponding test options, and does not support custom settings.

    7 Please inform in advance if the voltage(220V) does not match the actual needs so that we can provide customized solutions for you.

    8 At present, only Chinese and English interfaces are supported; if other languages are introduced, the software can be updated remotely.

    9 It is recommended to set the test time according to the test standard. The water temperature will rise due to long time test which has an impact on the test results.

    10 The data is calculated based on the dripping area, IPX1:0.6×0.6×(0.001-0.0015)=0.00036-0.00054m³/min(that is 0.36-0.54L/min).

    11 200mm is the distance from the nozzle to the sample specified in the standard, and the user needs to adjust the height of the turntable to meet the distance requirement.

    12 Multiple specifications of pendulum tubes can be provided, please confirm clearly before placing an order; if other specifications are added after purchase, the equipment needs to be returned to the factory to replace hardware and programs.

    13 The specifications of swing pipe for IPX3/4 rain test, as shown in the figure below:



    14 This distance is the range from the nozzle to the center of the turntable. If the user wants to extend the spraying distance, he needs to explain in advance.

    15 Since the IPX5 water spray is in a parabolic shape, the water spray range will be lower than this height, and the measured maximum water spray height is close to 550mm.

    16 The user needs to prepare an air compressor in advance (recommended gas storage capacity > 40L). If you need us to buy it on your behalf, you need to explain in advance.

    17 The photos may not match the actual ones, and are for user reference only.


    Product detail image:


    inner box


    Tags: Waterproof Testing Machine , IP Grade Rain Test Chamber , IPX1-9K Environmental Machine



    Quality Wide Use R400 Rain Test Chamber with Adjustable Spray Distance for IPX1-9K for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Yuexin Test Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)